Send Message
products

60TPH RO Filtration System Water Purifier Desalination Plant

Basic Information
Place of Origin: China
Brand Name: Jufu
Certification: ISO9001
Model Number: JFRO-60T
Minimum Order Quantity: 1 unit
Price: Negotiable
Packaging Details: Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
Delivery Time: 2-4 weeks
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Detail Information
RO Frame: SUS304/Carbon Steel (optional) Warranty: 1 Year
Capacity: 60T Per Hour Operating Pressure: 1.2-1.5MPa
Recovery Rate: 70% Desalination Rate: ≥99.5%
Function: Purification Water Control Valve: Manual/Automatic
Membrane Housing: FRP Pipe Material: U-PVC/Stainless Steel (optional)
High Light:

60TPH RO Filtration System

,

60TPH Water Purifier Desalination Plant

,

Industrial RO Filtration System


Product Description

60TPH RO Filtration System Water Purifier Desalination Plant

 

Reverse osmosis water system uses membrane separation technology to remove charged ions, inorganic substances, colloidal particles, bacteria and organic matter in water. It generally includes pretreatment system, reverse osmosis unit, post-treatment system, cleaning system and electrical control system. The purpose of pretreatment is to make the raw water meet the inlet requirements of the ro membrane separation unit and ensure the stable operation of the ro purification system. Reverse osmosis membrane system is the most economical and efficient purification method to remove more than 98% ions, organic matter and 100% microorganisms in raw water at one time. The ultra-purification post-treatment system further removes trace ions, organics and other impurities in the reverse osmosis pure water through a variety of integrated technologies, so as to meet the requirements of the final water quality index.

 

Technical specification of RO Water Treatment System

 

Model JFRO-60T
Host Size can be customized
Power 45KW
Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 1.2~1.5MPa
Recovery Rate 70%
Designed Water Inlet 85t/h
Outlet Flow 60t/h
Desalination Rate ≥99.5%
RO Frame SUS304
Membrane Size 8040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 60
Raw Water Pump CNP/NYP/GRUNDFOS (Optional)
High Pressure Pump CNP/NYP/GRUNDFOS (Optional)
Tank Material SS/FRP(Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing FRP
Number of Membrane housing 10
Pipe Material U-PVC/ Stainless steel (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Composition of RO Water Treatment System

 

Reverse osmosis purified water treatment system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.

 

1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.

2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.

3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.

4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.

5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.

 

Working Process of RO Water Treatment System

 

60TPH RO Filtration System Water Purifier Desalination Plant 0

 

 

Characteristics of RO Water Treatment System

 

1. The system can be fully automatic continuous production of water.

2. No chemical regeneration, easy operation and maintenance.

3. The core components of reverse osmosis system are CNP pump and Vontron reverse osmosis membrane.

4. The pure water tank automatically opens when the water level is low, and the original water tank automatically closes when the water level is high.

5. The system will automatically wash the reverse osmosis membrane about 90s, reducing the membrane fouling speed.

6. Water pump water shortage protection and low pressure protection switch.

7. The conductivity monitor will continuously test the water quality online and display data.

8. The whole system adopts water flowmeter, pressure gauge, solenoid valve, regulating control valve, control panel.

9. Reverse osmosis controller makes the whole reverse osmosis system run automatically.

10. Easy control and maintenance.

 

Applications of RO Water Treatment System


1. Preparation of space water, purified water, distilled water, etc.
2. Alcohol manufacturing and water reduction.
3. Pre-preparation of water in medicine, electronics and other industries.
4. Concentration, separation, purification and preparation of water distribution in chemical process.
5. Desalination and soft water for boiler feed water; desalination of sea water and brackish water.
6. Water and wastewater treatment in papermaking, electroplating, printing and dyeing and other industries.

 

Photos of RO Water Treatment System

 

60TPH RO Filtration System Water Purifier Desalination Plant 1

 

 

 

60TPH RO Filtration System Water Purifier Desalination Plant 2

 

 

60TPH RO Filtration System Water Purifier Desalination Plant 3

 

60TPH RO Filtration System Water Purifier Desalination Plant 4

 

 

60TPH RO Filtration System Water Purifier Desalination Plant 5

 

 

60TPH RO Filtration System Water Purifier Desalination Plant 6

 

 

60TPH RO Filtration System Water Purifier Desalination Plant 7

 

 

FAQ:

 

1. What is the material of ro water treatment system membrane?

 

Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

 

Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.

 

 

2. RO water treatment system configuration?

 

First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1

 

Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.

 

The arrangement of membrane components can be divided into series and parallel.

 

 

3. What is the shell film material and specification of ro water treatment system?

 

Material of membrane case: stainless steel and fiberglass (FRP)

 

Specification of membrane shell: four inch membrane shell 4040 (one core to four core)

 

8 inch membrane case 8040 (one to seven cores)

 

Water inlet: end water inlet, side water inlet

 

Contact Details
Chloe Cheung

Phone Number : +86 18001362005

WhatsApp : +8618001362005