Send Message
products

500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System

Basic Information
Place of Origin: China
Brand Name: Jufu
Certification: ISO9001
Model Number: JFRO-500L
Minimum Order Quantity: 1 unit
Price: Negotiable
Packaging Details: Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
Delivery Time: 2-4 weeks
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Detail Information
Host Size: 800x600x1600mm (can Be Customized) Power: 1.5KW
Power Supply: 220V /380V/460V - 50Hz/60Hz,220V 50Hz Can Be Customized Operating Pressure: 0.8-1.2MPa
Designed Water Inlet: 1000L/h Outlet Flow: 500L/h
Desalination Rate: ≥99.5% Raw Water Pump: CNP/NYP/GRUNDFOS (Optional)
Membrane Size: 4040 Number Of Membranes: 2
Membrane Elements: DOW/Hydranautics/Troy/Vontron (optional) Control Valve: Manual/Automatic
Control Valve Brand: FLECK/RUNXIN Tank Material: SS/FRP (Optional)
Pipe Material: U-PVC, Stainless Steel (Optional)
High Light:

500LPH One Stage RO Treatment System

,

Pure Water Purification Systems 500L/h

,

Automatic Reverse Osmosis Water Treatment


Product Description

500LPH One Stage RO Water Treatment System Pure Water Reverse Osmosis System
 
Product Introduction of RO Water Treatment System
When a pressure greater than the osmotic pressure is applied to the brine side of the membrane, the direction of water flow is reversed, and the water in the brine flows into the freshwater side, a phenomenon called reverse osmosis (reverse osmosis, abbreviated as RO). It is pretreated first and then treated with RO. Through these treatments, 99% of dissolved salts and harmful substances such as particles, colloids, organic impurities, heavy metal ions, bacteria, viruses and heat sources can be removed. The desalination rate of the system reaches 96-98%, and the conductivity of the effluent is ≤ 10μ S/cm.
 
The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.
 
Technical Specifications of RO Water Treatment System
 
 

500LPH Reverse Osmosis System
ModelJFRO-500L
Host Size800x600x1600mm (can be customized)
Power1.5KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet1000L/h
Outlet Flow500L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes2
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Application fields of RO water treatment system
Water treatment system treat raw water in several procedures in order to meet the bottled drinking water standard.
This system uses water pressure pump to increase the water supply pressure; sand filter is used to remove Plankton, Moss, Suspension, Colloid and so on. Active carbon filter is used to remove strange smell, chlorine, chloride, organic matter and heavy mental, lower color and optimize water quality. Sodium softer is used to remove the calcium and magnesium ions in water. Micro filter is used to remove the tiny impurity. Hollow fiber Ultra filter can remove impurity, colloid, phenolic compounds, chloride, germ and all the harmful substance, meanwhile keep all beneficial minerals in water. Reverse osmosis can move all the things in the water and to make raw water to be pure water.

 
 
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
 
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 0
 
Photos of reverse osmosis water treatment system
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 1
 
 
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 2
 
 
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 3
 
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 4
 
 
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 5
 
 
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 6
 
 
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 7
 
 
500LPH RO Water Treatment System One Stage Pure Water Reverse Osmosis System 8
 
 
FAQ:
 
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
 
Model 4040 is designed by 0.25m3/h
 
Model 8040 is designed by 1-1.2m3/h
 
2. What is the material of mechanical filter?
 
Carbon steel, stainless steel, fiberglass
 
3.What are the multi-way control valves?
 
Manual control valve, automatic control valve
 
Multi - way control valve is divided into: filter valve and softening valve
 
Automatic control valve is divided into: time type and flow type.
 
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

Contact Details
Sophia

Phone Number : +8613891958785

WhatsApp : +8618001362005