Place of Origin: | China |
---|---|
Brand Name: | Jufu |
Certification: | ISO9001 |
Model Number: | JFRO-1000L |
Minimum Order Quantity: | 1 unit |
Price: | Negotiable |
Packaging Details: | Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping. |
Delivery Time: | 2-4 weeks |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Host Size: | 1000x600x1600mm (can Be Customized) | Power: | 2.2KW |
---|---|---|---|
Power Supply: | 220V /380V/460V - 50Hz/60Hz,220V 50Hz Can Be Customized | Operating Pressure: | 0.8-1.2MPa |
Designed Water Inlet: | 2000L/h | Outlet Flow: | 1000L/h |
Desalination Rate: | ≥99.5% | Raw Water Pump: | CNP/NYP/GRUNDFOS (Optional) |
Membrane Size: | 4040 | Number Of Membranes: | 4 |
Membrane Elements: | DOW/Hydranautics/Troy/Vontron (optional) | Control Valve: | Manual/Automatic |
Control Valve Brand: | FLECK/RUNXIN | Tank Material: | SS/FRP (Optional) |
Pipe Material: | U-PVC, Stainless Steel (Optional) | ||
High Light: | FRP Tank Water RO Equipment,2.2KW Ro Water System,Industrial Reverse Osmosis Filtration System |
Reverse Osmosis System Ro Water System RO Equipment Industrial Ro Plant
Product Introduction of RO Water Treatment System
The reverse osmosis system is an important part of the pure water production device. In order to ensure the long-term stability of the reverse osmosis system, it is necessary to carry out pretreatment for different influent water quality to avoid pollution or blockage of the reverse osmosis system due to poor water quality.
For the reverse osmosis system, the incoming water is customarily divided into groundwater, tap water, surface water, seawater, waste water (reclaimed water), etc. These water bodies are affected by various factors, different geographical conditions, and different seasonal climates lead to the characteristics and characteristics of the water body. The impurities it contains are different, so the reverse osmosis pretreatment process will also be different.
The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.
Technical Specifications of RO Water Treatment System
1000LPH Reverse Osmosis System | |
Model | JFRO-1000L |
Host Size |
1000x600x1600mm (can be customized) |
Power | 2.2KW |
Power Supply |
220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 50% |
Designed Water Inlet | 2000L/h |
Outlet Flow | 1000L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 4040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 4 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP (Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | SS/FRP (Optional) |
Pipe Material | U-PVC, Stainless steel (Optional) |
Advantages of RO water treatment system:
Reverse osmosis equipment belongs to physical desalting method, which has many advantages.
1) Non-phase-change physical method was used to desalinate and purify the saline water under norma temperature.
2) Desalting rate of single membrane element is 99.3% and can remove colloid, organics, bacteria, virus and all kinds of heavy metals in water at the same time.
3) With water pressure as the driving force, energy consumption is the lowest among many treatment methods.
4) No need for large amount of chemical treatment, no elimination of chemical waste liquid, no environmental pollution, and the recovery rate is over 70%.
5) High automation program, automatic stop in case of ailure, with automatic protection function.
6) The system is simple, easy to operate, and the water quality is stable.
7) Equipment covers small area, compact structure, reliable operation and high water quality.
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
Photos of Reverse Osmosis Water Treatment System
FAQ:
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3.What are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.